Product Information
| Manufacturer | LEM |
|---|---|
| Manufacturer Part No | HX 10-NPCopy |
| Manufacturer Standard Lead Time | 16 weeks |
| Order Code | 1617426 |
| Product Range | HX Series |
| Technical Datasheet | |
| Sensor Output Type | Voltage |
| Supply Voltage Range | ± 12V to ± 15V |
| Supply Voltage DC Min | 12V |
| Supply Voltage DC Max | 15V |
| Measured Current | AC / DC / Pulsed |
| Current Measuring Range DC | -30A to 30A |
| Accuracy | 1% |
| Current Sensor Technology | Open Loop, Hall Effect |
| Current Measuring Range AC | -30A to 30A |
| Response Time | 3µs |
| Primary Current | 10A |
| Accuracy % | 1% |
| Sensor Mounting | Through Hole |
| Operating Temperature Min | -25°C |
| Operating Temperature Max | 85°C |
| Product Range | HX Series |
| SVHC | No SVHC (25-Jun-2025) |
Product Overview
The HX 10-NP is a Current Transducer with isolated plastic case construction. The HX series current transducer features as an electronic measurement of currents DC, AC, pulsed, mixed with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit). Isolation test voltage 3000V. It is used for AC variable speed, battery supplies, uninterruptible power supplies (UPS), switched mode power supplies (SMPS) and DC motor drives.
- Hall effect measuring principle
- Low power consumption
- 2 Isolated power windings
- Low insertion losses
- Easy to mount with automatic handling system
- Small size and space saving
- Only one design for wide current rating range
- High immunity to external interference
- UL94V-0 Flammability rating
Applications
Sensing & Instrumentation, Motor Drive & Control, Power Management, Industrial
Technical Specifications
| Sensor Output Type | Voltage |
|---|---|
| Supply Voltage DC Min | 12V |
| Measured Current | AC / DC / Pulsed |
| Accuracy | 1% |
| Current Measuring Range AC | -30A to 30A |
| Primary Current | 10A |
| Sensor Mounting | Through Hole |
| Operating Temperature Max | 85°C |
| SVHC | No SVHC (25-Jun-2025) |
| Supply Voltage Range | ± 12V to ± 15V |
|---|---|
| Supply Voltage DC Max | 15V |
| Current Measuring Range DC | -30A to 30A |
| Current Sensor Technology | Open Loop, Hall Effect |
| Response Time | 3µs |
| Accuracy % | 1% |
| Operating Temperature Min | -25°C |
| Product Range | HX Series |
Technical Docs (2)
Legislation and Environmental
| Country of Origin: Country in which last significant manufacturing process was carried outCountry of Origin: | China Country in which last significant manufacturing process was carried out |
|---|---|
| Tariff No: | 85043129 |
| US ECCN: | EAR99 |
| EU ECCN: | NLR |
| RoHS Compliant: | Yes RoHS |
| RoHS Phthalates Compliant: | Yes RoHS |
| SVHC: | No SVHC (25-Jun-2025) |
| Download Product Compliance Certificate | Product Compliance Certificate |
| Weight (kg): | .01202 |